BVXPH - SYNTILO 9154
- MSDS: BVXPH
- Manufacturer: CASTROL INDUSTRIAL INC
- Product Name: SYNTILO 9154
- National Stock Number: 9150-00N054394
Product Identification
Product ID:SYNTILO 9154
MSDS Date:08/30/1993
FSC:9150
NIIN:00N054394
MSDS Number: BVXPH
Responsible Party
DOWNER GROVE, IL 60515-1280
US
Emergency Phone: 708-241-4000
Info Phone: 708-241-4000
Preparer: RICARDO SIMMONS
Cage: CASTI
Contractor
Telephone: 213-890-4420
Cage: 98308
Ingredients
BORIC ACID, DISODIUM SALT; (BORON SODIUM SODIUM TETRABORATE
CAS: 1330-43-4
RTECS: VZ2275000
Fraction By Weight: 1-5%
OSHA PEL 10 MG/M3
ACGIH TLV: 1 MG/M3
ETHANOL,2,2',2"-NITRILOTRI-
CAS: 102-71-6
RTECS: KL9275000
Fraction By Weight: 10-15%
ACGIH TLV: 5 MG/M3
053.82 G/L 00.449 LBS/GAL
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:LD50 (RAT,ORAL) >5.0 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:CONCENTRATE WILL CAUSE
IRRITATION. INHAL:MISTS OF THE CONCENTRATE & DILUTIONS MAY CAUSE
RESPIRATORY IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:CONC-IMMED FLUSH W/PLENTY OF WATER FOR @ LEAST 15
MINUTES. GET MED ATTN IMMED. REC USE DILUTION:FLUSH W/PLENTY OF
WATER FOR @ LEAST 15 MINS. GET MED ATTN IF IRRIT OCCURS. SKIN:WASH
W/SOAP & WATER . IF IRRIT OCCURS, GET MED ATTN. WASH CLTHG BEFORE
REUSE. INHAL:IF RESP DISCOMFORT/IRRIT OCCURS, MOVE PERSON TO FRESH
AIR. SEE MD IF DISCOMFORT/IRRIT CONTINUES. INGEST:GET MED ATTN
IMMEDIATELY.
Fire Fighting
Flash Point:NONE
Extinguishing Media:WATER, DRY CHEMICAL, CO*2, OR "ALCOHOL" FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL FIRE EXPOSED CONTAINERS WITH WATER SPRAY TO
PREVENT RUPTURE.
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:ABSORB W/INERT MATERIAL (E.G., DRY
SAND/EARTH), THEN PLACE IN CHEMICAL WASTE CNTNR. FLUSH RESIDUAL
SPILL W/WATER. FOR LARGE SPILLS, DIKE FOR LATER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT CUT OR WELD EMPTY DRUMS UNLESS
THORO CLEANED. AVOID BREATHING MISTS. AVOID CONT W/EYES. DO NOT
INGEST.
Other Precautions:KEEP DRUMS CLSD WHEN NOT IN USE. BRING PRODUCT TO
ROOM TEMPERATURE BEFORE USE.
Exposure Controls
Respiratory Protection:GOOD INDUST HYGIENE PRACTICES RECOMMEND THAT
ENGINEERING CONTROLS BE USED TO REDUCE ENVIRON CONC TO THRESHOLD
LIM VALUE (TLV)/PERMISSIBLE EXPOS LIM (PEL). IF ANY ASSOC (SUPDAT)
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES, SUCH AS RUBBER.
Eye Protection:SFTY GLASSES W/SIDE SHLD/CHEM GOGG.
Other Protective Equipment:EYEWASH FACILITY. APPROPRIATE CLOTHING TO
AVOID SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:1.072 +/-0.007 (H*20=1). PH:8.9-9.3. RESP PROT:TLV/PEL IS
EXCEEDED, PROVIDE NIOSH/MSHA APPRVD RESPIRATORY PROTECTION.
Chemical Properties
HCC:V6
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:SUPP DATA
pH:SUPDAT
Evaporation Rate & Reference:<1 (BUTYL ACETATE =1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, YELLOW FLUID
Percent Volatiles by Volume:30
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:POTENTIAL COMBUSTION PRODUCTS ARE
OXIDES OF CARBON, NITROGEN, AND BORON.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE AND FEDERAL
REGULATIONS. DISPOSAL OF THIS MATL TO THE LAND MAY BE BANNED BY
FEDERAL LAW (40 CFR 268).
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.